久久天天躁狠狠躁夜夜不卡,国产精一品亚洲二区在线播放,人妻洗澡被强公日日澡,91精品国产成人网在线观看,久久天天躁狠狠躁夜夜躁2014

您好!歡迎來到安徽得潤電氣技術有限公司官方網站!

收藏得潤電氣| 在線留言| 網站地圖| 關于得潤電氣

全(quan)國服務(wu)熱線(xian): 400-128-7988
你所在的位置:首頁 » 電氣成套設備技術分享

想了解10KV無功補償裝置的內部組成和工作方法

返回列表 來(lai)源:得潤電(dian)氣
掃一掃!想了解10KV無功補償裝置的內部組成和工作方法掃一掃!
瀏覽:-發布日期:2021-10-11 14:30【

得潤電氣10kV無功補償柜

10kV無(wu)功(gong)(gong)(gong)補償裝置是電(dian)力(li)系(xi)統中(zhong)經常會(hui)用(yong)到的(de)(de)(de)電(dian)氣(qi)成(cheng)套設備,它(ta)的(de)(de)(de)用(yong)途是根據配(pei)電(dian)變壓器(qi)無(wu)功(gong)(gong)(gong)負荷(he)狀況,自動(dong)分步投切(qie)并聯在配(pei)電(dian)變壓器(qi)3~20kV母線(xian)的(de)(de)(de)電(dian)容(rong)器(qi)組,提供相應(ying)的(de)(de)(de)容(rong)性無(wu)功(gong)(gong)(gong)功(gong)(gong)(gong)率。該裝置突破了(le)原電(dian)力(li)系(xi)統中(zhong)電(dian)容(rong)器(qi)組使用(yong)整組進行固定(ding)(ding)補償投入時造(zao)成(cheng)過補而切(qie)除后母線(xian)無(wu)功(gong)(gong)(gong)功(gong)(gong)(gong)率又補償不足的(de)(de)(de)缺點,使母線(xian)功(gong)(gong)(gong)率因數大(da)幅度提高(gao)并能穩(wen)定(ding)(ding)在一定(ding)(ding)的(de)(de)(de)水平,從而穩(wen)定(ding)(ding)了(le)系(xi)統電(dian)壓、提高(gao)了(le)變壓器(qi)的(de)(de)(de)利用(yong)率。下面(mian)來介紹一下得潤(run)電(dian)氣(qi)生產(chan)的(de)(de)(de)10kV無(wu)功(gong)(gong)(gong)補償裝置。

得潤電氣10kV線路無功補償裝置  

1 10kV線路無功補償系統闡述 
  10kV線(xian)(xian)(xian)路(lu)(lu)(lu)無(wu)(wu)功(gong)(gong)(gong)(gong)補(bu)(bu)(bu)償(chang)(chang)系(xi)統是(shi)(shi)電(dian)(dian)力運(yun)(yun)行中(zhong)(zhong)(zhong)重要(yao)技術之一,主要(yao)指的(de)(de)(de)是(shi)(shi)按照標準(zhun)化要(yao)求,全(quan)面(mian)優化原有(you)管理系(xi)統,實(shi)現管理系(xi)統的(de)(de)(de)快速升(sheng)級,使(shi)供(gong)(gong)(gong)(gong)電(dian)(dian)單位(wei)和部門(men)能夠隨(sui)時(shi)、及時(shi)對供(gong)(gong)(gong)(gong)電(dian)(dian)全(quan)線(xian)(xian)(xian)路(lu)(lu)(lu)無(wu)(wu)功(gong)(gong)(gong)(gong)電(dian)(dian)壓(ya)各種(zhong)狀況實(shi)現掌(zhang)握與了(le)(le)解(jie),從(cong)(cong)根(gen)本上達(da)到分析整體線(xian)(xian)(xian)路(lu)(lu)(lu)負荷分布是(shi)(shi)否均勻,確(que)保電(dian)(dian)壓(ya)運(yun)(yun)行過(guo)程(cheng)(cheng)中(zhong)(zhong)(zhong)保持合格,能夠促使(shi)供(gong)(gong)(gong)(gong)電(dian)(dian)部門(men)有(you)效(xiao)提高(gao)(gao)電(dian)(dian)能數(shu)據和檢(jian)測、計量(liang)以(yi)及檢(jian)測整線(xian)(xian)(xian)路(lu)(lu)(lu)數(shu)據的(de)(de)(de)準(zhun)確(que)程(cheng)(cheng)度,保證供(gong)(gong)(gong)(gong)電(dian)(dian)穩定與可靠性。技術的(de)(de)(de)發展代替了(le)(le)傳統的(de)(de)(de)運(yun)(yun)行方(fang)式(shi),目前來(lai)看(kan),10kV線(xian)(xian)(xian)路(lu)(lu)(lu)無(wu)(wu)功(gong)(gong)(gong)(gong)補(bu)(bu)(bu)償(chang)(chang)主要(yao)作(zuo)用(yong)(yong)在(zai)(zai)三個(ge)方(fang)面(mian),一是(shi)(shi)在(zai)(zai)變(bian)電(dian)(dian)站10kV母線(xian)(xian)(xian)按主變(bian)容量(liang)15%左(zuo)右集(ji)中(zhong)(zhong)(zhong)安(an)裝(zhuang)補(bu)(bu)(bu)償(chang)(chang)電(dian)(dian)容器組(zu);二(er)是(shi)(shi)在(zai)(zai)用(yong)(yong)戶配變(bian)低壓(ya)側(ce)分散安(an)裝(zhuang)低壓(ya)補(bu)(bu)(bu)償(chang)(chang)電(dian)(dian)容器柜;三是(shi)(shi)在(zai)(zai)10kV線(xian)(xian)(xian)路(lu)(lu)(lu)若干(gan)符合中(zhong)(zhong)(zhong)心處或線(xian)(xian)(xian)路(lu)(lu)(lu)2/3處集(ji)中(zhong)(zhong)(zhong)安(an)裝(zhuang)10kV線(xian)(xian)(xian)路(lu)(lu)(lu)補(bu)(bu)(bu)償(chang)(chang)電(dian)(dian)容器組(zu),不(bu)(bu)同的(de)(de)(de)方(fang)式(shi)有(you)不(bu)(bu)同的(de)(de)(de)技術要(yao)求,取得效(xiao)果(guo)也有(you)所不(bu)(bu)同,在(zai)(zai)實(shi)際調節(jie)過(guo)程(cheng)(cheng)中(zhong)(zhong)(zhong),就需要(yao)根(gen)據問題導向,做(zuo)好(hao)安(an)裝(zhuang)與調試,保證供(gong)(gong)(gong)(gong)電(dian)(dian)效(xiao)果(guo)、提高(gao)(gao)用(yong)(yong)電(dian)(dian)質量(liang)。但(dan)是(shi)(shi),從(cong)(cong)實(shi)際效(xiao)果(guo)來(lai)看(kan),第(di)三種(zhong)補(bu)(bu)(bu)償(chang)(chang)方(fang)式(shi)具備自身較多的(de)(de)(de)優勢(shi),與前兩種(zhong)補(bu)(bu)(bu)償(chang)(chang)方(fang)式(shi)相比(bi),具備裝(zhuang)置(zhi)集(ji)中(zhong)(zhong)(zhong)、減(jian)少(shao)線(xian)(xian)(xian)路(lu)(lu)(lu)損耗、設備利(li)用(yong)(yong)率(lv)(lv)高(gao)(gao)和便于管理維護等優點(dian),在(zai)(zai)當前的(de)(de)(de)供(gong)(gong)(gong)(gong)電(dian)(dian)企(qi)業(ye)中(zhong)(zhong)(zhong)已經(jing)(jing)實(shi)現了(le)(le)非常廣泛(fan)的(de)(de)(de)推廣與應用(yong)(yong),實(shi)現了(le)(le)良好(hao)的(de)(de)(de)供(gong)(gong)(gong)(gong)電(dian)(dian)補(bu)(bu)(bu)償(chang)(chang)效(xiao)果(guo),能夠進一步優化系(xi)統,對無(wu)(wu)功(gong)(gong)(gong)(gong)功(gong)(gong)(gong)(gong)率(lv)(lv)補(bu)(bu)(bu)償(chang)(chang)的(de)(de)(de)好(hao)壞,直接影響著(zhu)(zhu)電(dian)(dian)網運(yun)(yun)行有(you)功(gong)(gong)(gong)(gong)功(gong)(gong)(gong)(gong)率(lv)(lv)比(bi)例,大(da)大(da)減(jian)少(shao)供(gong)(gong)(gong)(gong)電(dian)(dian)投入,節(jie)省(sheng)資金(jin)投入,全(quan)面(mian)有(you)效(xiao)的(de)(de)(de)提高(gao)(gao)供(gong)(gong)(gong)(gong)電(dian)(dian)企(qi)業(ye)經(jing)(jing)濟效(xiao)率(lv)(lv),保證企(qi)業(ye)收益(yi)。在(zai)(zai)實(shi)際應用(yong)(yong)中(zhong)(zhong)(zhong),供(gong)(gong)(gong)(gong)電(dian)(dian)企(qi)業(ye)均會(hui)在(zai)(zai)10kV線(xian)(xian)(xian)路(lu)(lu)(lu)方(fang)面(mian)安(an)裝(zhuang)無(wu)(wu)功(gong)(gong)(gong)(gong)補(bu)(bu)(bu)償(chang)(chang)裝(zhuang)置(zhi),這樣做(zuo)的(de)(de)(de)目的(de)(de)(de)無(wu)(wu)非就是(shi)(shi)減(jian)少(shao)供(gong)(gong)(gong)(gong)電(dian)(dian)過(guo)程(cheng)(cheng)中(zhong)(zhong)(zhong)配網損耗,保證生產效(xiao)率(lv)(lv)提升(sheng),在(zai)(zai)城鎮配電(dian)(dian)過(guo)程(cheng)(cheng)中(zhong)(zhong)(zhong),起著(zhu)(zhu)重要(yao)的(de)(de)(de)作(zuo)用(yong)(yong),10kV線(xian)(xian)(xian)路(lu)(lu)(lu)安(an)裝(zhuang)無(wu)(wu)功(gong)(gong)(gong)(gong)補(bu)(bu)(bu)償(chang)(chang)裝(zhuang)置(zhi)不(bu)(bu)論是(shi)(shi)從(cong)(cong)效(xiao)果(guo)看(kan),還(huan)是(shi)(shi)從(cong)(cong)經(jing)(jing)濟效(xiao)益(yi)上看(kan),都(dou)有(you)著(zhu)(zhu)必要(yao)的(de)(de)(de)現實(shi)意義(yi)。 

10kV無功補償裝置廠家 安徽得潤電氣 

 2 安裝地點選擇 
  安裝(zhuang)(zhuang)地點(dian)至(zhi)關(guan)重要(yao)(yao),直接(jie)影(ying)響著(zhu)運行的(de)(de)(de)效(xiao)率,在安裝(zhuang)(zhuang)前(qian),需要(yao)(yao)科學論證,做出正(zheng)確(que)(que)的(de)(de)(de)選(xuan)擇。從(cong)專業(ye)的(de)(de)(de)角(jiao)度看,無(wu)(wu)功(gong)(gong)補(bu)(bu)(bu)(bu)償(chang)裝(zhuang)(zhuang)置安裝(zhuang)(zhuang)地點(dian)會(hui)對(dui)無(wu)(wu)功(gong)(gong)補(bu)(bu)(bu)(bu)償(chang)最后的(de)(de)(de)實(shi)(shi)現(xian)(xian)能(neng)力與(yu)效(xiao)果(guo)產生(sheng)重大改變,影(ying)響整(zheng)體供(gong)電(dian)(dian)效(xiao)能(neng)。供(gong)電(dian)(dian)企業(ye)要(yao)(yao)想實(shi)(shi)現(xian)(xian)線(xian)(xian)路(lu)(lu)(lu)(lu)安裝(zhuang)(zhuang)補(bu)(bu)(bu)(bu)償(chang)裝(zhuang)(zhuang)置的(de)(de)(de)效(xiao)果(guo),就需要(yao)(yao)從(cong)多方面全(quan)面考慮,避免出現(xian)(xian)不良因素,在安裝(zhuang)(zhuang)時(shi),不但要(yao)(yao)全(quan)面考慮功(gong)(gong)率因素,而且還要(yao)(yao)仔細考慮節能(neng)降損的(de)(de)(de)實(shi)(shi)際(ji)問(wen)(wen)題。在實(shi)(shi)際(ji)安裝(zhuang)(zhuang)過程(cheng)中,如把補(bu)(bu)(bu)(bu)償(chang)裝(zhuang)(zhuang)置安裝(zhuang)(zhuang)到(dao)線(xian)(xian)路(lu)(lu)(lu)(lu)的(de)(de)(de)最前(qian)面,補(bu)(bu)(bu)(bu)償(chang)裝(zhuang)(zhuang)置無(wu)(wu)功(gong)(gong)負(fu)(fu)荷不能(neng)得(de)到(dao)釋放,仍然要(yao)(yao)通(tong)過線(xian)(xian)路(lu)(lu)(lu)(lu)傳輸到(dao)達用(yong)電(dian)(dian)設(she)備,這時(shi)就會(hui)出現(xian)(xian)無(wu)(wu)功(gong)(gong)電(dian)(dian)流的(de)(de)(de)長距離流動,這種情況極容易出現(xian)(xian)線(xian)(xian)路(lu)(lu)(lu)(lu)損耗的(de)(de)(de)問(wen)(wen)題,這種方式,雖然解決了(le)補(bu)(bu)(bu)(bu)償(chang)的(de)(de)(de)問(wen)(wen)題,但從(cong)實(shi)(shi)際(ji)效(xiao)果(guo)看并不理想,線(xian)(xian)路(lu)(lu)(lu)(lu)功(gong)(gong)率因數得(de)到(dao)提高的(de)(de)(de)同(tong)時(shi),卻并沒(mei)有(you)(you)達到(dao)節能(neng)降損目標(biao),由此可見,安裝(zhuang)(zhuang)無(wu)(wu)功(gong)(gong)補(bu)(bu)(bu)(bu)償(chang)裝(zhuang)(zhuang)置位(wei)置的(de)(de)(de)選(xuan)擇非常關(guan)鍵(jian),只有(you)(you)選(xuan)擇正(zheng)確(que)(que)的(de)(de)(de)位(wei)置,才(cai)能(neng)從(cong)根本上解決問(wen)(wen)題,實(shi)(shi)現(xian)(xian)有(you)(you)效(xiao)運行,安裝(zhuang)(zhuang)時(shi),對(dui)地點(dian)一定要(yao)(yao)嚴格(ge)論證,盡量選(xuan)擇無(wu)(wu)功(gong)(gong)負(fu)(fu)荷中心的(de)(de)(de)區(qu)域,只有(you)(you)這樣,才(cai)能(neng)減少線(xian)(xian)路(lu)(lu)(lu)(lu)無(wu)(wu)功(gong)(gong)電(dian)(dian)流以最大限(xian)度實(shi)(shi)現(xian)(xian)就地平衡(heng)。如果(guo)供(gong)電(dian)(dian)企業(ye)在10kV線(xian)(xian)路(lu)(lu)(lu)(lu)補(bu)(bu)(bu)(bu)償(chang)是對(dui)線(xian)(xian)路(lu)(lu)(lu)(lu)某一段進(jin)行截取補(bu)(bu)(bu)(bu)償(chang),就會(hui)導致補(bu)(bu)(bu)(bu)償(chang)設(she)備檢(jian)測的(de)(de)(de)不全(quan)面,對(dui)補(bu)(bu)(bu)(bu)償(chang)裝(zhuang)(zhuang)置以上負(fu)(fu)荷無(wu)(wu)法實(shi)(shi)現(xian)(xian)快速檢(jian)測,裝(zhuang)(zhuang)置電(dian)(dian)源側負(fu)(fu)荷得(de)不到(dao)確(que)(que)認與(yu)檢(jian)測,沒(mei)有(you)(you)形成可利用(yong)的(de)(de)(de)數據與(yu)反饋,所以只有(you)(you)通(tong)過恒定整(zheng)條線(xian)(xian)路(lu)(lu)(lu)(lu)不過補(bu)(bu)(bu)(bu),而能(neng)夠使(shi)得(de)補(bu)(bu)(bu)(bu)償(chang)點(dian)允許過補(bu)(bu)(bu)(bu)。

10kV線路自動補償裝置 安徽得潤電氣 
  3 補償方式選擇 
  補償方式是當前供電企業在10kV線路安裝無功補償裝置所要具體考慮到的問題之一。不同的補償方式會產生不同的效果,目前來看,絕大多數供電企業對10kV線路補償一般采用的模式是在柱上安裝固定電容器的方式,在技術處理上,按線路最小補償量或采用“三分之二”法則來確定電容器容量。通過訓類方式對10kV線路進行補償,實現連續性,但當線路負荷達到最高峰的時候,就會出現欠補現象,導致線損率增加,而達不到良好的補償作用。隨著科技的進步與創新,多級、多點無功自動補償方式得到快速推廣與應用,但其投資成本巨大,雖然效果較好,但卻存在許多不足和弊端,投入產出比的回報率低,收效時間過長,供電企業一般采用固定補償與自動補償兩種方式同時使用的方式,通過科學良好的模式組合,形成最佳控制。通過這種方式進行補償,不但能夠大大的提高工作效率,同時也能實現線路負荷的自動化控制,不論是供電用電高峰還是低谷,線路補償均能實現良好效果,極大的減少了配電線路無功輸送流量,保證了無功輸送距離的長度,從根本上有效解決了線路損耗過大的問題,使電力供應更加穩定可靠,提高了供電能力與供電質量,使企業能夠獲取更多的回報,滿足社會經濟發展需求。 
  4 10kV線路無功補償實際節能方案 
  通過上文的分析,我們已經明確了10kV線路無功補償裝置安裝地點及補償方式,要想實現良好的運行效果,電力企業在安裝無功補償裝置時,需要通過更加科學實用的方式進行選擇安裝,采用固定補償與自動補償相結合的模式,是當前最為實用的組合,在安裝地點上盡量選擇無功負荷中心位置,只有這樣,才能通過恒定整條線路不過補使補償點允許過補,從本質上,全面提高10kV線路無功補償系統速度,下面我們通過實際案例進行分析。 
  4.1 確定線路的補償容量 
  要想實現10kV線路無功補償效果,就需要在進行裝置前,進一步確認好補償容量,只有這樣,才能從根本上達到改善目的。安裝無功補償裝置之前,一定要綜合性考慮到各方面可能存在的問題,避免出現不良影響因素,電力企業需要通過專項、全面、客觀的調查與分析,科學合理的選定控制范疇,從中進一步確定無功補償裝置容量范圍,使確定的補償容量能真正為10kV線路服務,減少線損實現節能環保要求。電力企業設置無功補償裝置容量要遵循最大程度降低線路損耗這一基本原則,就是設置的前提與條件,進行確認時,一定要做好平均值計算,保證所設置的無功補償裝置的容量最好為10kV線路平均無功負荷的2/3為最佳。 
  4.2 確定補償裝置安裝位置 
  位置的選擇要嚴格進行,在確保無功補償裝置安裝到10kV線路無功負荷中心位置基礎上,還要保證無功就地平衡原則,從而實現配網主線無功電流減少,通過對各條配網線路安裝無功補償裝置,進一步控制好線損問題。只有電力企業對電容器最佳安裝位置科學選擇,保證無功補償容量符合標準規范,才能針對性的改善電壓質量,穩定供電運行,實現10kV線路無功補償系統的社會效用,確保用電需求增大的同時,實現社會經濟可持續發展。 
  5 無功補償裝置安裝注意事項 
  無功補償裝置在進行安裝時,會受空間、環境、工作量、成本等條件的限制,不同的影響因素會形成不同的問題,只有通過科學合理的配置,才能達到節能減排目標。農村廣大地區電網無功補償裝置安裝,重點需要考慮到每條線路單點補償方法,通過這種方式,盡量簡化控制,避免形成分組投切,避免頻繁出現故障。 
  6 結束語 
  隨著無(wu)功補償方法(fa)及配置技(ji)術的不(bu)斷完善,其優勢作用(yong)會日益(yi)突顯,自身蘊藏的潛力將會不(bu)斷發揮作用(yong),只有不(bu)斷進(jin)行探索(suo)研究,才(cai)能進(jin)一步(bu)提升供電質量與運行效益(yi)。 


安徽得潤電氣技術有限公司作為一家生產10kV無功補償裝置廠(chang)家,希望(wang)您在需要使用(yong)10kV無功(gong)補償裝置之前(qian),可以咨詢我(wo)們,給您寶貴的(de)建議,合(he)理的(de)配置,這樣(yang)即(ji)節省您的(de)成(cheng)本(ben)又提高工作效率。

掃一掃二維碼了(le)解更多詳(xiang)情:

得潤電器訂閱號 得潤電氣(qi)訂閱號(hao)

得潤電器頭條號 得潤(run)電氣頭條(tiao)號

更多詳情請咨詢安徽得潤電氣技術有限公司


熱賣產品推薦

  • 施耐德MVnex 中置式金屬封閉開關柜
    MVnex 中壓開關柜安徽得潤電氣自主生產的施耐德授權柜,MVnex 中置式中壓開關柜產品十分安全可靠,柜體采用了全新的結構設計,實…
  • ABB中壓開關柜UniSafe
    ABB中壓開關柜uniSafe中壓柜是ABB授權得潤電氣生產的中壓金屬封閉開關設備.靈活的方案設計,滿足客戶的不同需求;完善的機械聯鎖,…
  • 施耐德授權Blokset 低壓開關柜
    Blokset系列開關柜(簡稱B柜)是施耐德電氣公司授權得潤電氣專門為其低壓配電產品而設計,它適用于400Hz以下,額定工作電壓690V.…
  • MNS2.0型低壓抽屜式開關柜
    MNS2.0型低壓抽出式開關柜(以下稱開關柜)是我公司采用了瑞士ABB公司的MNS系列低壓開關柜技術并加以綜合改進后開發的,是目前國…

相關電氣成套設備技術分享

最新資訊文章