漏(lou)(lou)(lou)電(dian)保(bao)(bao)護(hu)(hu)裝置是低壓(ya)配電(dian)柜中常用的一種保(bao)(bao)護(hu)(hu)元器件,當發生漏(lou)(lou)(lou)電(dian)和(he)觸電(dian)時(shi),且達到保(bao)(bao)護(hu)(hu)器所(suo)限定的動作(zuo)(zuo)電(dian)流值時(shi),就立即在限定的時(shi)間內動作(zuo)(zuo)自動斷開電(dian)源進行保(bao)(bao)護(hu)(hu)。漏(lou)(lou)(lou)電(dian)保(bao)(bao)護(hu)(hu)裝置主要按其保(bao)(bao)護(hu)(hu)功(gong)能和(he)用途分(fen)類進行敘述,一般(ban)可分(fen)為漏(lou)(lou)(lou)電(dian)保(bao)(bao)護(hu)(hu)繼(ji)電(dian)器、漏(lou)(lou)(lou)電(dian)保(bao)(bao)護(hu)(hu)開關和(he)漏(lou)(lou)(lou)電(dian)保(bao)(bao)護(hu)(hu)插座(zuo)三種。下面詳細講解(jie)一下漏(lou)(lou)(lou)電(dian)保(bao)(bao)護(hu)(hu)裝置。
一、漏電保護(hu)裝置的結構(gou)組成
(1)檢測(ce)元件(jian)。由零(ling)序互(hu)感(gan)器組成,檢測(ce)漏電電流(liu),并發出信號。
(2)中(zhong)間(jian)環(huan)節(jie)。將微弱的漏電(dian)信(xin)號放大,按裝置不同(tong)(放大部件可采用機械裝置或電(dian)子裝置),構(gou)成電(dian)磁式(shi)保護器相電(dian)子式(shi)保護器。
(3)執(zhi)行機構。收到信號后,主(zhu)開(kai)關由閉合位置轉換到斷開(kai)位置,從而(er)切斷電(dian)源,是被保護電(dian)路(lu)脫(tuo)離電(dian)網(wang)的跳閘部件。
二、漏(lou)電(dian)保護裝置的原理
(1)當電(dian)氣設(she)備發生漏電(dian)時(shi),出(chu)(chu)現兩種異常(chang)現象:一是(shi),相電(dian)流(liu)的平(ping)衡遭到破壞,出(chu)(chu)現零(ling)(ling)序電(dian)流(liu);二(er)是(shi),正常(chang) 時(shi)不帶電(dian)的金(jin)屬外(wai)(wai)殼出(chu)(chu)現對地電(dian)壓(正常(chang)時(shi),金(jin)屬外(wai)(wai)殼與(yu)大(da)地均為零(ling)(ling)電(dian)位)。
(2)零序(xu)電(dian)(dian)流(liu)互(hu)(hu)感(gan)器的(de)作(zuo)用漏電(dian)(dian)保護器通過電(dian)(dian)流(liu)互(hu)(hu)感(gan)器檢測取得異常訊(xun)號,經過中間機構(gou)轉換(huan)傳遞,使(shi)執(zhi)行機構(gou)動作(zuo),通過開關裝(zhuang)置斷(duan)開電(dian)(dian)源。電(dian)(dian)流(liu)互(hu)(hu)感(gan)器的(de)結構(gou) 與(yu)變壓(ya)器類(lei)似,是由(you)兩個(ge)互(hu)(hu)相(xiang)絕緣繞在同一鐵心(xin)上的(de)線圈組(zu)成。當一次線圈有剩余電(dian)(dian)流(liu)時,二次線圈就會感(gan)應(ying)出電(dian)(dian)流(liu)。
(3)漏(lou)電保護器(qi)工作(zuo)原(yuan)理將漏(lou)電保護器(qi)安裝在線(xian)路中(zhong),一次(ci)線(xian)圈與(yu)電網的(de)線(xian)路相連接,二次(ci)線(xian)圈與(yu)漏(lou)電保護器(qi)中(zhong)的(de)脫(tuo)扣(kou)器(qi)連接。
三、注意事項
(1)漏(lou)電(dian)(dian)保(bao)護(hu)器(qi)(qi)適用于(yu)(yu)電(dian)(dian)源中性點直接(jie)(jie)(jie)接(jie)(jie)(jie)地(di)(di)或經過電(dian)(dian)阻、電(dian)(dian)抗接(jie)(jie)(jie)地(di)(di)的(de)(de)(de)低(di)壓配電(dian)(dian)系統。對(dui)于(yu)(yu)電(dian)(dian)源中性點不(bu)(bu)接(jie)(jie)(jie)地(di)(di)的(de)(de)(de)系統,則不(bu)(bu)宜采(cai)用漏(lou)電(dian)(dian)保(bao)護(hu)器(qi)(qi)因為后者不(bu)(bu)能構成(cheng)(cheng)泄漏(lou)電(dian)(dian)氣(qi)回路(lu),即(ji)(ji)使發生(sheng)了(le)接(jie)(jie)(jie)地(di)(di)故障(zhang),產生(sheng)了(le)大(da)于(yu)(yu)或等于(yu)(yu)漏(lou)電(dian)(dian)保(bao)護(hu)器(qi)(qi)的(de)(de)(de)額定動(dong)作(zuo)電(dian)(dian)流,該保(bao)護(hu)器(qi)(qi)也不(bu)(bu)能及(ji)時動(dong)作(zuo)切(qie)(qie)斷電(dian)(dian)源回路(lu);或者依(yi)靠人體接(jie)(jie)(jie)能故障(zhang)點去構成(cheng)(cheng)泄漏(lou)電(dian)(dian)氣(qi)回路(lu),促使漏(lou)電(dian)(dian)保(bao)護(hu)器(qi)(qi)動(dong)作(zuo),切(qie)(qie)斷電(dian)(dian)源回路(lu)。但(dan)是,這對(dui)人體仍不(bu)(bu)安全。顯而易見,必須具備接(jie)(jie)(jie)地(di)(di)裝置(zhi)的(de)(de)(de)條件,電(dian)(dian)氣(qi)設備發生(sheng)漏(lou)電(dian)(dian)時,且漏(lou)電(dian)(dian)電(dian)(dian)流達到動(dong)作(zuo)電(dian)(dian)流時,就能在(zai)0.1秒內(nei)立即(ji)(ji)跳閘,切(qie)(qie)斷了(le)電(dian)(dian)源主回路(lu)。
(2)漏(lou)電(dian)保護器保護線路的(de)工作中性線N要通(tong)過零序(xu)電(dian)流(liu)互(hu)感(gan)器。否則(ze),在接通(tong)后,就會有(you)一(yi)個不(bu)平衡電(dian)流(liu)使漏(lou)電(dian)保護器產生誤動作。
(3)接零保(bao)護線(PE)不(bu)準(zhun)通(tong)過零序(xu)電(dian)(dian)流(liu)(liu)互感器。因為保(bao)護線路(PE)通(tong)過零序(xu)電(dian)(dian)流(liu)(liu)互感器時(shi),漏(lou)電(dian)(dian)電(dian)(dian)流(liu)(liu)經(jing)PE保(bao)護線又(you)回穿過零序(xu)電(dian)(dian)流(liu)(liu)互感器,導致電(dian)(dian)流(liu)(liu)抵消,而互感器上檢測不(bu)出(chu)漏(lou)電(dian)(dian)電(dian)(dian)流(liu)(liu)值。在出(chu)現故障時(shi),造成漏(lou)電(dian)(dian)保(bao)護器不(bu)動作,起不(bu)到(dao)保(bao)護作用。
(4)漏電保護器后面的工作中性線N與保護線(PE)不能合(he)并(bing)為(wei)一(yi)體(ti)。如果二(er)者合(he)并(bing)為(wei)一(yi)體(ti)時(shi),當出現漏電故障(zhang)或人體(ti)觸電時(shi),漏電電流經(jing)由(you)電流互(hu)感(gan)器(qi)回流,結(jie)果又雷同(tong)于情況(3),造成漏電保護器(qi)拒絕(jue)動(dong)作。