10KV高壓無功集中補償裝置詳情說明,全在這里
MSCHC高壓無功集(ji)中補償裝置
一.產品概述
MSCHC型高壓無(wu)功(gong)集中(zhong)補(bu)(bu)償(chang)(chang)裝置(zhi),是將固定容(rong)(rong)量的(de)(de)(de)電(dian)容(rong)(rong)器(qi)(qi)組 并(bing)聯連接在配電(dian)變壓器(qi)(qi)3~35kV母線(xian)上,提(ti)(ti)供(gong)固定容(rong)(rong)量的(de)(de)(de)容(rong)(rong)性無(wu)功(gong)功(gong)率(lv),補(bu)(bu)償(chang)(chang)感性無(wu)功(gong)功(gong)率(lv),改善功(gong)率(lv)因數,穩定系統電(dian)壓,從而降低線(xian)路損耗,提(ti)(ti)高變壓器(qi)(qi)傳輸容(rong)(rong)量,提(ti)(ti)高整體的(de)(de)(de)電(dian)力傳輸效率(lv)。裝置(zhi)由并(bing)聯電(dian)容(rong)(rong)器(qi)(qi)、串(chuan)聯電(dian)抗器(qi)(qi)、放電(dian)線(xian)圈、避雷器(qi)(qi)、控制和保護裝置(zhi)等組成。主要應用(yong)于(yu)3~35kV負(fu)荷波(bo)動不大的(de)(de)(de)交流電(dian)力系統中(zhong)。
二.型號及其含義
3.電氣原理圖
QF:斷路器
QS:隔離開關
TV:放電線圈
TA:電流互感器
FU:噴逐式熔斷器
FV:氧化鋅避雷器
L:鐵芯串聯電抗器
C:并(bing)聯電(dian)力電(dian)容器
GSN:高壓(ya)帶電(dian)顯示(shi)閉鎖裝置
說(shuo)明:虛線框內為我公司提供的(de)設備;
四.產品特色
1.設(she)備建造(zao)費用低、運行和維護簡(jian)單、運行可靠(kao)性(xing)高;
2.積木式設(she)計,柜(ju)與柜(ju)之間硬母排聯接,運(yun)行可靠,且可擴展柜(ju)體數以增加產品(pin)容量(liang);
3.每套(tao)裝置(zhi)都要進行諧(xie)振(zhen)校驗(yan),選擇容量(liang)時盡量(liang)避開諧(xie)振(zhen)放大區,或選擇適(shi)當的電(dian)抗率(lv),以避開諧(xie)振(zhen)條件,確保裝置(zhi)在各種工(gong)況下都能安全(quan)運行;
4.除采用噴逐式熔斷器或內熔絲作(zuo)為單臺電(dian)(dian)容器的過(guo)流(liu)保(bao)(bao)護(hu)(hu)外,還設有零序電(dian)(dian)壓保(bao)(bao)護(hu)(hu)、差壓保(bao)(bao)護(hu)(hu)、橋差保(bao)(bao)護(hu)(hu)、中線不平衡電(dian)(dian)流(liu)保(bao)(bao)護(hu)(hu)、雙星形(xing)不平衡電(dian)(dian)流(liu)和橋差保(bao)(bao)護(hu)(hu)混合(he)保(bao)(bao)護(hu)(hu)等保(bao)(bao)護(hu)(hu)方(fang)案可供選擇(ze),可使裝置長期穩定運。
五.正常使用條件
最高運(yun)行電壓≤1.1Un;
最(zui)大過載(zai)電流≤1.35ln;
周(zhou)圍環境(jing)溫度-25?+45℃;
室內(nei)相對濕度不超(chao)過90 % (溫度為(wei)2 5℃時);
安(an)裝地(di)點海拔高度不超(chao)過(guo)2000m;沒有劇烈的(de)振動,垂(chui)直(zhi)傾斜度不超(chao)過(guo)5度;沒有導電性塵埃、火災(zai)、爆(bao)炸危險;沒有足以(yi)腐蝕金屬和破壞絕(jue)緣(yuan)的(de)氣體。
六.產品規格(ge)、型號、參數、柜體尺(chi)寸
裝置型號 | 額定容量(kvar) | 額定(ding)電流 A | 電容(rong)容(rong)量(kvar) 及數量 | 柜體數量 | 柜體總尺寸 Wx Dx H(mm) |
MSCHA6(10)- 750/3 | 750 | 65.6(39.3) | 250x3 | 1 | 1200x1600x2400 |
MSCHA6(10)- 1000/3 | 1000 | 87.5(52.5) | 334x3 | 1 | 1200x1600x2400 |
MSCHA6(10)- 1200/3 | 1200 | 105(63) | 400x3 | 1 | 1200x1600x2400 |
MSCHA6(10)-1500/3 | 1500 | 131(78.7) | 250x6 | 1 | 1500x1600x2400 |
MSCHA6(10)- 1800/3 | 1800 | 157.4(94.5) | 300x6 | 1 | 1500x1600x2400 |
MSCHA6(10)-2100/3 | 2100 | 183.7(110.2) | 350x6 | 2 | 2400x1600x2400 |
MSCHA6(10)-2400/3 | 2400 | 210(126) | 400x6 | 2 | 2400x1600x2400 |
MSCHA6(10)-3000/3 | 3000 | 262.4(157.5) | 250x12 | 3 | 3600x1600x2400 |
MSCHA6(10)-3600/4 | 3600 | 314.9(189) | 300x12 | 3 | 3600x1600x2400 |
MSCHA6(10)-4200/4 | 4200 | 367.4(220.4) 9 | 350x12 | 4 | 5000x1600x2600 |
MSCHA6(10)-4800/4 | 4800 | 420(252) | 400x12 | 4 | 5000x1600x2600 |
MSCHA6(10)-5400/5 | 5400 | 472.4(283.4) | 300x18 | 5 | 5700x1600x2600 |
MSCHA6(10)-6000/5 | 6000 | 524.9(314.9) | 334x18 | 5 | 5700x1600x2600 |
MSCHA10-7200/5 | 7200 | --(377.9) | 400x18 | 5 | 5700x1600x2600 |
MSCHA10-8100/5 | 8100 | --(425.2) | 450x18 | 5 | 5700x1600x2600 |
MSCHA10-9000/5 | 9000 | --(472.4) | 500x18 | 5 | 5700x1600x2600 |
說(shuo)明(ming):1.容量在5000kvar以上的(de)設(she)備均提(ti)供(gong)W=1000mm的(de)專用進線柜一臺;
2..電抗器(qi)的(de)電抗率(lv)一般選(xuan)配6%,但如(ru)果容(rong)量在諧振放大(da)區(qu)的(de),則經計(ji)算選(xuan)用(yong)合適的(de)電抗率(lv),以(yi)避開諧振條件。
七.訂貨須知
1.產品型號及參數,補償容量;
2.系統和負載(zai)的(de)性質、大小、阻抗特性;
3.裝置接(jie)入點的系(xi)統(tong)電壓,系(xi)統(tong)主接(jie)線(xian)
4.系統的(de)運行(xing)方式(shi),各(ge)運行(xing)方式(shi)下的(de)最(zui)大與最(zui)小短路容量(liang)
掃一(yi)掃二維(wei)碼了解(jie)更多詳情:
得潤(run)電氣訂閱號
得潤電氣(qi)頭條號
更多詳情請咨詢安徽得潤電氣技術有限公司